· Check that master is on a dedicated 120 Volt 15 amp circuit breaker.
· Possible defective transformer (TE5).
· Possible defective master.
If there is no communication to the door:
· Make sure to perform “DOOR TALK” correctly. (press “Listen” and “Talk”
simultaneously to talk to the door. Release to listen to the door).
· Check that door speaker is connected properly at master unit and door
station.
· Check for short or open on door station cable.
· Check that master is not in “off” position
· Check that intercom and master volume levels are set properly.
· Possible defective door station.
· Possible defective master.
If there is no chime, or continuous chime:
· Check that the chime module (MC3 or MC8) is connected correctly to the
master unit.
· Check that the bell button wires are connected to screws on back of bell
button. (Bell button should be lit if connected properly to the chime module.)
· Check that room switches at master are in “RADIO INT” or “INTERCOM”
position. (No chime when stations are switched to the “Monitor” or “Off”
position.)
· Check that “INTERCOM VOLUME” and room station volume controls are
adjusted properly. (See AUDIO SETTINGS.)
· Check for short or open on bell button wires. (Short will cause Error 9).
· Possible defective chime module.